Sharing key considerations for chiller selection and cleaning procedures.


Release Date:

2020-01-15

Sharing key considerations for chiller selection and cleaning procedures.
The function of a chiller is to supply chilled water to equipment across various industries, helping to enhance product precision and production efficiency. However, the chiller market today is highly fragmented, making it crucial to select a model that suits your specific needs. So, how do you choose the right chiller? And once purchased, how should you clean it? Today, we’ll provide a detailed guide to help you.
 Sharing key considerations for chiller selection and cleaning procedures.
I. Considerations for Selecting a Chiller
 
1. Standard chiller nominal cooling capacity under reference operating conditions: chilled water inlet temperature 12°C, chilled water outlet temperature 7°C, ambient temperature 35°C. Power supply configuration: 3P–380V–50Hz, with allowable voltage fluctuation of ±10% and allowable phase-to-phase voltage difference of ±2%.
 
2. When testing this chiller, don’t focus solely on its flow rate; also consider the temperature you require. The chiller is equipped with either an imported temperature controller or a programmable controller for precise temperature regulation.
 
3. When testing a chiller, you need to determine whether you’re using direct cooling or indirect cooling. Direct cooling involves feeding water directly into the chiller; the chilled water then flows straight into your process equipment for cooling, which typically delivers better performance. When selecting a unit, be sure to take your specific on-site process requirements into account.
 
II. Steps for Cleaning the Chiller
 
1. Shut off the chilled water supply to the chiller and drain all water from the unit’s internal components and piping to prevent residual water from causing corrosion or, at low temperatures, freezing and expanding within the copper tubing. At the same time, unscrew the drain plug beneath the pump to completely remove any remaining water, thereby avoiding ice formation in the water system due to extremely low ambient temperatures, which could lead to evaporator rupture, refrigerant leakage, or damage to the pump impeller.
 
2. Turn off the power and inspect each component for wear; replace any components that show signs of wear.
 
3. Clean the fan of the air-cooled chiller to keep it in a clean condition.
 
4. For the water tank of a coil-type evaporator, inspect for scale and other debris and remove them.
 
5. Monitor lubricant usage through data logging and replace the lubricant at scheduled intervals in accordance with established service intervals to maintain optimal lubrication performance.
 
6. The chilled water piping of the chiller unit must be thermally insulated, as insulation not only prevents significant refrigeration loss but also inhibits condensation from forming on the outer pipe surface. For example: with a chilled water temperature of 10°C and an ambient temperature of 30°C, a 25-meter-long metal pipe with a surface area of 25 m² can experience heat radiation of 750 kcal/h—roughly equivalent to about 10% of the cooling capacity produced by a three‑horsepower compressor or approximately 6% of that generated by a five‑horsepower compressor.
 
7. Air-cooled chillers are one type of chiller that uses a compressor to cool tap water to a specified temperature, thereby enhancing the cooling of molds or machinery. When used as standalone units, they feature an integrated fan for heat dissipation and comprise three interconnected systems: the refrigerant circulation system, the water circulation system, and the electrical control system.
 