Chiller Evaporator Leak Repair and Replacement


Release Date:

2014-08-02

The primary failure mode of evaporators in reactor chillers is leakage, which can manifest in several ways: poor cooling performance or complete lack of cooling. Aluminum blow‑formed or aluminum coil evaporators tend to experience higher failure rates after several years of service, whereas copper evaporators—and the galvanized‑wire‑tube drawer‑type evaporators commonly found in today’s market—generally exhibit lower failure rates. (1) Repair of Evaporator Leakage Faults The main causes of evaporator leaks are defects in the evaporator material itself, as well as minor leaks that develop over time due to refrigerant pressure, liquid erosion, or corrosion. Additionally, using sharp objects such as knife tips to handle food can also lead to damage.

The primary failure mode of evaporators in reactor chillers is leakage, which can manifest in several ways: poor cooling performance or complete lack of cooling. Aluminum blow‑molded or aluminum coil evaporators tend to experience a higher failure rate after several years of service, whereas copper evaporators—and the galvanized‑wire‑tube drawer‑type evaporators commonly found in today’s market—exhibit lower failure rates.
(1) Repair of evaporator leakage faults

The primary cause of evaporator leaks is defective evaporator material; during operation, exposure to refrigerant pressure and liquid erosion, or corrosion, can lead to minute leaks. Additionally, using a sharp object such as a knife tip to retrieve food may puncture the evaporator surface, resulting in refrigerant leakage.
Regardless of the type of evaporator used, a reactor chiller always has an additional section of copper tubing at each end, resulting in joints such as copper–aluminum and copper welds. Most evaporator leaks occur at these joints. Therefore, when an evaporator leaks, locating the faulty joint becomes especially critical.
In some reactor chillers, the internal fittings are grouped within one or a few compact areas, marked with a recessed imprint on the back or covered by a removable metal plate. When a leak occurs in the evaporator and the fittings need to be located, simply cut open the metal plate over the recessed area or remove the removable cover, then excavate the foam insulation to expose the fittings.
For a reactor chiller without markings or visible piping, if the routing of the internal pipework and the locations of the fittings are unknown, you can locate the exposed connection pipes of the lower evaporator by identifying the points where they pass through the insulation layer. Then, on the back of the chiller—opposite the partition between the freezer and refrigerator compartments—drill an opening, remove the insulation, and expose the fittings for inspection. If additional fittings need to be located, follow the piping to trace them.
When locating leaks, pay close attention to the number of joints. Most reactor chillers have copper–aluminum joints at both ends of the evaporators, while the evaporator–capillary tube and evaporator–compressor suction line connections use brazed copper joints. After identifying the leak by opening the chiller’s rear panel, select an appropriate repair method based on the material involved. Regardless of the technique used, the evaporator must be leak‑tested: pressurize it with nitrogen at 0.8 MPa and inspect for leaks using a detergent solution or soapy water. Only after confirming there are no leaks should the unit be reinstalled and put into service.
(2) Replacement of the evaporator
When the evaporator has numerous leaks and is severely damaged, the rear or top panel of the reactor chiller can be removed, the foam insulation layer scraped away, and the existing evaporator taken out and replaced with a new one of the same specifications; the resulting voids can then be filled with foam for repair. Alternatively, a slightly smaller new evaporator can be fitted inside the original unit, with its connecting pipes routed through the back of the original evaporator to join the original piping. If no suitable replacement evaporator is available, a copper tube of the same diameter and length as the original can be custom‑wound and inserted in its place.

 