What is the maintenance of a thermal management system for new energy vehicles?


Release Date:

2022-09-21

The temperature control range of the thermal management unit for new-energy vehicles is wide, and the entire process requires no replacement of the heat-transfer fluid, resulting in minimal fluid consumption. The closed-loop circulation of the heat-transfer fluid ensures its safety and longevity. High‑temperature pre‑cooling and cooling can directly reduce the temperature from elevated levels.

   New Energy Vehicle Thermal Management Unit It offers a wide temperature control range, eliminates the need to replace the heat-transfer fluid throughout the process, and minimizes fluid consumption. The closed-loop circulation of the heat-transfer fluid ensures both safety and longevity. High‑temperature precooling and cooling can directly reduce temperatures from elevated levels.

  

 New Energy Vehicle Thermal Management Unit

  I. Daily Maintenance and Repair of Thermal Management Systems for New Energy Vehicles:

  1. Press the status key on the keyboard to confirm that no fault messages are displayed. For the display messages and fault‑clearance procedures, refer to the Microcomputer Control Operation Manual.

  2. Refrigerant leakage: Visually inspect the heat exchanger, compressor, and piping for damage or leaks.

  3. Operating Conditions: Press the display key to read the operating pressure and temperature from the controller, and verify that these values fall within the operating ranges specified in the microcomputer control operation manual.

  4. Oil Level: After the compressor has been running at full load for approximately half an hour, check the oil level in the oil separator. The oil level should be between the upper and lower sight glasses of the oil separator.

  5. Refrigerant Charging: After the system is started or when the operating level is changed, you may occasionally observe some bubbles through the sight glass. After the system has been running steadily for a few minutes, the bubbles will dissipate, and the refrigerant liquid will become visible through the liquid lens.

  6. Oil Heater: After the unit is shut down, the compressor oil heater will be turned on to prevent refrigerant from condensing and dissolving into the lubricating oil, which could damage the compressor. Do not disconnect the power supply while the unit is off. If it is necessary to disconnect the main power, also close the compressor’s suction, discharge, and motor‑cooling service shut‑off valves.

  II. New Energy Vehicle Thermal Management Unit Regular maintenance of:

  1. Regularly clean the filter to ensure clean water quality within the system and prevent damage to the unit caused by clogging due to dirt buildup.

  2. The surrounding area should be kept clean, dry, and well-ventilated. Regular cleaning of the air-side heat exchanger can help maintain its optimal heat transfer performance.

  4. New-energy vehicle refrigeration and heating control units: Regularly inspect the water system’s make-up and venting devices to ensure they are functioning properly, thereby preventing air from entering the system, reducing water circulation, and avoiding difficulties in water flow that could compromise the unit’s cooling performance and operational reliability.

  5. Regularly inspect the power supply and electrical system wiring to ensure secure connections, and check electrical components for any abnormal operation. If any abnormalities are detected, repair or replace the affected parts immediately. The equipment must be reliably grounded.

  6. Regularly inspect the operating condition of all components of the unit and verify that the refrigeration system’s operating pressure is within the normal range. Check for oil contamination at the unit’s pipe joints and oil‑filling valves, ensuring there are no leaks in the refrigeration system.

  III. New Energy Vehicle Thermal Management Unit Performance:

  1. The temperature control range of the heating–cooling unit is 5°C to 300°C, and its combined cooling and heating functions can meet diverse temperature requirements under various operating conditions. Utilizing a coordinated compressor‑operation technology, the refrigeration circuits are independently configured. Time‑shifted, staggered start-up minimizes grid disturbances, ensures stable high‑performance operation of the compressors, and effectively reduces energy consumption. With fully automatic temperature control, the system supports continuous 24‑hour operation.

  2. Employing compressor‑based refrigeration combined with high‑pressure linked heating or direct hot‑wire heating, and controlled in real time by the control system, this solution can meet both cold‑water and hot‑water requirements, maintaining the water temperature at the setpoint while delivering low vibration, low noise, efficient heat exchange materials, and high energy efficiency.

  3. Long service life. The evaporator and condenser are strategically positioned to ensure smooth oil return, thereby extending the compressor’s service life and maintaining high efficiency.

  4. New Energy Vehicle Thermal Management Unit: The refrigeration compressor and other key components are all brand‑new imports, offering high specifications and excellent cost‑effectiveness. It features an all‑metal frame, a sleek design, and a full baked‑on paint finish for superior rust resistance. Cooling and heating performance.

  5. Both the oil‑heating temperature control unit and the cooling water chiller are equipped with intelligent temperature‑control systems. The equipment is designed for continuous 24‑hour operation.