Key Points for Using a Low-Temperature Cascade Refrigeration System


Release Date:

2022-11-24

This low-temperature cascade chiller consists of two or more refrigeration cycles. It is also known as a cascade compression refrigerator or a cascade‑type compressor chiller. Below, we’ll outline its key advantages, hoping to provide valuable guidance when you’re making your purchasing decision.

   Low-temperature cascade chiller This equipment consists of two or more refrigeration cycles. It is a cascade compression chiller, also known as a cascade‑type compressor chiller. Below, we’ll outline its advantages, hoping to provide you with valuable guidance when making your purchase.

 Low-temperature cascade chiller

  Although a cascade refrigeration system can achieve evaporating temperatures lower than those of a single-stage compression refrigeration cycle, it is constrained by the thermophysical properties of the refrigerant and the operating characteristics of the compressor. When the evaporating temperature is very low, multi‑stage compression refrigeration cycles are typically employed. There are no specific requirements in this regard; at such conditions, the appropriate refrigeration cycle must be selected. The primary reason is that the evaporating temperature must remain above the refrigerant’s freezing point; otherwise, the refrigerant cannot circulate. If the evaporating temperature of the refrigeration cycle falls below the refrigerant’s freezing point, the refrigerant will solidify and cease to flow, thereby losing its ability to circulate. For example, R717 has a freezing point of −77.7°C, and the lower limit for an R717 refrigeration cycle is precisely −77.7°C. In cascade systems, medium‑temperature refrigerants are used in the high‑temperature stage, while low‑temperature refrigerants are typically employed in the low‑temperature stage. Each circuit may utilize either a single‑stage or a two‑stage compression refrigeration cycle. These two circuits are connected via a condenser–evaporator assembly: in a cascade system, the condenser serves as the condenser for the low‑temperature circuit, and the evaporator functions as the evaporator for the high‑temperature circuit.

   Low-temperature cascade chiller It can both maintain an appropriate evaporating pressure at lower temperatures and ensure a moderate condensing pressure at ambient conditions. Alternatively, three refrigerants can be combined to form low‑temperature, medium‑temperature, and high‑temperature refrigeration cycles. In practice, most refrigerants used are organic compounds with low freezing points—for example, R13 freezes at −180°C—so when they vaporize at low saturation temperatures, their impact on the vacuum cleaner’s suction performance is minimal. However, the critical point of low‑temperature cascade systems is relatively low; for instance, R13 has a critical temperature of 28.8°C and a critical pressure of 3.861 MPa. When the condensing temperature reaches or exceeds 28.8°C, R13’s condensing pressure not only becomes very high but also surpasses its critical pressure. Under normal operating conditions, such low‑temperature cascade units cannot perform cooling and condensation as effectively as conventional coolants like water or air, which serve as high‑ and medium‑temperature refrigerants. The equipment primarily employs branded electronic thermostats with a temperature control accuracy of ±1°C. All control components are conveniently located on the front panel of the industrial stackable freezer. Simply press the switch, set the desired temperature, and the unit will operate automatically—quick and easy. As our factory’s flagship product, we sincerely appreciate the strong support from both new and longstanding customers. While ensuring the reliability and quality of our products, we also strive to offer competitive pricing to benefit our valued clients.

  The above article provides an overview of… Low-temperature cascade chiller Some key information about its usage. If you weren’t familiar with it before, now’s the time to take a look. In the next installment, we’ll cover more related topics—don’t forget to tune in.

  



Zhejiang Loda Refrigeration Technology Co., Ltd.

Address: Xiayang Village, Xiazhuhu Subdistrict, Deqing County, Huzhou City, Zhejiang Province

Fax: 0571-88526093

Email: 409611431@qq.com