Introduction to the Condensation Process in Exhaust Gas Condensation and Recovery Units
Release Date:
2022-12-26
Waste Gas Condensation and Recovery Unit It is used to separate condensable components from gases and is currently employed primarily to recover valuable solvents from exhaust streams. However, condensation alone does not suffice to meet exhaust emission standards. Therefore, in the purification of organic waste gases, condensation‑recovery units are mainly designed to reclaim solvents and serve as a pre‑treatment step in the overall purification process. The transition of a substance from the vapor phase to the liquid phase is known as condensation. Next, let’s take a closer look at the condensation‑recovery process employed by these units.

Principle of the condensation process
The underlying principle is that substances exhibit different saturation vapor pressures at varying temperatures. When cooling or pressurization reduces the partial pressure of organic components in the exhaust gas to equal the saturation vapor pressure at a given temperature, these organic compounds condense into liquid form and are separated from the gas stream. Organic waste‑gas purification by condensation is typically categorized into three temperature ranges and three distinct types of coolants or refrigerants.
Greater than 0: Cooling water or chilled water can also be used directly; sometimes air cooling is employed.
If below 50, use frozen brine.
Below 120, only liquid nitrogen cooling can be used.
Exhaust gas condensation‑recovery units are highly effective at purifying high‑boiling‑point VOCs but perform poorly for low‑boiling‑point compounds, typically achieving only partial condensation. When the solvent concentration in the exhaust gas is below 10 g/m³, condensation‑based treatment generally requires temperatures below −40 °C to meet emission standards. The typical flow rate range for organic waste gases treated by condensation is less than 3,000 m³/h (at standard conditions), with VOC concentrations in the exhaust gas typically ranging from 0.5% to 10%.
Waste Gas Condensation and Recovery Unit The primary component is the condenser, which can be classified into direct-contact condensers and surface‑heat‑exchanger condensers—namely, direct condensation and indirect condensation. In direct-contact condensation, VOC vapors in the exhaust gas come into direct contact with a cold liquid and are condensed. As with absorption equipment, such condensers often employ spray towers, Venturi scrubbers, or packed towers. Direct-contact condensation typically uses water to cool the exhaust gas; this approach is simple and requires low capital investment, but it can give rise to secondary pollution and pose challenges in treating the resulting wastewater. Surface‑heat‑exchanger condensers mainly include shell-and-tube heat exchangers and finned‑tube heat exchangers; the latter use air as the cooling medium, known as air coolers. Both methods have been employed in fine chemical production, differing primarily in their scope of application, operating conditions, and scale.
Exhaust Gas Condensation and Recovery Unit: By comparing the direct condensation method with the indirect condensation method, it was found that the direct cooling approach is more advantageous, offering benefits in the following four areas.
1. High heat exchange efficiency, minimal energy loss, and significant energy savings.
2. Because it is different, there is no need for regular cleaning like in the indirect condensation method; the operation is simple and does not adversely affect the production line.
3. Thanks to its excellent heat transfer performance, stable production, and high, consistent recovery efficiency that does not decline with increasing operating time.
4. By adding sodium hydroxide to the cooling water, hydrogen sulfide—a harmful gas—was converted into sodium sulfide, thereby improving the air quality in the vicinity of the plant. An expert designed a prototype of a pipe‑bend heat exchanger equipped with an automatic control system. This device was used to recover ethyl acetate and ethanol. Experiments were conducted to assess the effects of varying condensation temperatures and heat‑transfer durations on recovery efficiency; the condensation temperatures tested were −18°C, −15°C, and −7°C, while the heat‑transfer times were 5, 10, 20, 25, 30, and 40 minutes. The results indicated that lower temperatures led to higher recovery efficiencies: at −18°C, the maximum recovery efficiency for ethyl acetate was 70%, and for ethanol it was 96.77%.
Waste gas condensation and recovery unit: Whether the heat‑exchange time is too long or too short, the recovery efficiency remains suboptimal; the optimal heat‑exchange duration is 20–25 minutes. This process can enhance solvent recovery efficiency; further studies should investigate the effects of operating pressure, inlet gas concentration, and other factors to identify suitable operating conditions. In principle, condensation is only viable when the waste‑gas flow rate is low and the concentration of condensable components is relatively high. Using water and air as cooling media typically fails to meet emission standards, necessitating additional purification. For the treatment of large‑volume, low‑concentration organic waste gases, condensation is usually combined with other methods such as adsorption and catalytic oxidation.
Waste Gas Condensation and Recovery Unit It serves solely as pre‑treatment feedwater prior to the purification process, reducing both the capital and operating costs of downstream exhaust‑gas treatment equipment. When organic waste gases are condensed at low temperatures, the moisture, carbon dioxide, and other constituents they contain can freeze, potentially causing partial blockage of the equipment or impairing heat transfer. Consequently, in addition to periodic removal by heating, the concentration of organic components during solvent recovery via condensation invariably remains within the flammable range; thus, stringent safety requirements must be met.